5500sc Silica Analyzer, 1 Channel, Reagents included
Lower Maintenance, Less Downtime
The 5500sc silica analyzer needs only two liters of reagent to perform unattended for up to 90 days; twice as long as the Series 5000. The industry's only pressurized reagent delivery system eliminates the frequent maintenance associated with pumps. Prognosys which is a predictive diagnostic system allows you to be proactive in your maintenance. Warning LEDs, and high-visibility notification screens let you avoid unplanned downtime. No more dripping reagents on the instrument, the floor, or your clothing while fumbling with tubes and straws. Simply match the color-coded cap to the sealed reagent bottle and twist gently. Grab Sample In and Grab Sample Out features allow quick analysis of a grab sample poured into the analyzer, and facilitate taking a sample out of the online silica analyzer to verify in a lab test.
Two liters of reagent are required for the silica analyzer to perform unattended for up to 90 days; twice as long as the Series 5000.
The industry's only pressurized reagent delivery system eliminates the frequent maintenance associated with pumps.
Prognosys, the predictive diagnostic system, allows you to be proactive in your maintenance. Warning LEDs, and high-visibility notification screens let you avoid unplanned downtime.
No more dripping reagents on the instrument, the floor, or your clothing while fumbling with tubes and straws. Simply match the color-coded cap to the sealed reagent bottle and twist gently.
Grab Sample In and Out features allow quick analysis of a grab sample poured into the analyzer, and facilitate taking a sample out of the analyzer to verify in a lab test.
Accuracy | 0 - 500 µg/L: ±1% or ±1 µg/L of reading, whichever is greater; 500 - 5000 µg/L: ±5% |
Alarm | Four relays output; type: not powered SPDT relays, each rated at 5 A resistive, 240 VAC maximum Connection: 18 to 14 AWG wire, 18 AWG stranded recommended |
Application | Pure water / Power |
Certifications | CE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991, +A1:2000 ) KC (EN 61326-1: 2006) C-tick (EN 61326-1: 2006) cETLus (UL 61010-1: 2012; NEMA 250: 2003; CSA C22.2 No 61010-1: 2012) |
Controller Compatibility | SC200, SC1000 |
Enclosure Rating | IP56 / NEMA 4X |
Fitting Type | Sample line and sample bypass drain: 6 mm (¼-in.) Air purge inlet: 6 mm (¼-in.) |
Grab Sample | Grab Sample In and Grab Sample Out capability |
Light Source | Class 1M LED (light emitting diode) with a peak wavelength of 810 nm |
Lower Limit of Detection (LOD) | 0.5 µg/L |