HeaderMain
CL17sc Colorimetric Chlorine Analyzer
Category: Water Analysis
Sub Category: Process/Inline Analysis
Share
Add To Cart

CL17sc Colorimetric Chlorine Analyzer with Standpipe Installation Kit and Reagents for Free Chlorine

Range

0 - 10 mg/L free or total residual chlorine

Accuracy

± 5% or ± 0.04 mg/L (whichever is greater) from 0 - 5 mg/L Cl2

± 10% from 5 - 10 mg/L Cl2

Lower Limit of Detection (LOD)

0.03 mg/L

Cycle Time

2.5 minutes

Inlet Pressure

0.3 - 5.2 bar (4.5 - 75 psig) supplied to Y-strainer

0.1 - 0.3 bar (1.5 - 5 psig) supplied to analyzer

Inlet

¼-inch OD polyethylene tube, quick-disconnect fitting

Drain

½-inch ID flexible hose

Air Purge

Optional with 3/8-inch quick-connect fitting and tubing; 0.003 m3/min at 1.38 bar (20 psig) maximum

Sample Requirements

Y-strainer filtration with 40-mesh screen or higher

Sample Flow Rate

60 - 200 mL/min through the instrument

Sample Temperature

5 - 40 °C (41 - 104 °F)

Operating Temperature Range

5 - 40 °C (41 - 104 °F)

Operating Humidity

0 - 90% relative humidity, non-condensing

Interferences

Other oxidizing agents such as bromide, chlorine dioxide, permanganate, and ozone will cause a positive interference. Hardness must not exceed 1,000 mg/L CaCO3.

Reagent Consumption

0.5 L of buffer solution and 0.5 L of indicator solution in 31 days

Certifications

CE compliant with: EN 61326-1, CISPR 11, EN 50581

ACMA RCM

South Korea KC Certificate

North America: FCC Supplier’s Declaration of Conformance, IEC/EN 60529, ICES-003

Light Source

LED, measurement at 510 nm, 1 cm light pathlength

Enclosure Rating

IP66

Mounting

Wall mount

Power Requirements (Voltage)

12 VDC, 400 mA maximum (supplied by the controller)

Dimensions (H x W x D)

342 mm x 329 mm x 177 mm

Weight

4.1 kg (9.0 lbs.)

The Next Standard in Chlorine Analysis
Built on a legacy of reliability in online chlorine analysis, the advanced design of the CL17sc reduces routine maintenance touch time and provides powerful diagnostic features and enhanced connectivity. The result is less hassle, minimized risk of data loss, and even more reliable information to empower your decision making.

Maintenance made easy
The CL17sc reduces your routine maintenance touch time with programmable alerts, simplified tubing replacement, and step-by-step maintenance instructions.

Peace of mind through comprehensive diagnostics
With upgraded features like a flow meter, colorimeter window, multi-color status light, and predictive diagnostic software, you know your instrument is operating as intended.

Expanded connectivity. Increased flexibility.
By pairing the CL17sc with Hach’s SC controller platform, your options increase significantly: internal data logging; external analog and digital communication alternatives; and multiparameter instrument flexibility.
The CL17sc is compliant with US EPA regulation 40 CFR 141.74. Both Method 4500-CL G and Method 334.0 can be used for measuring residual chlorine in drinking water.