HeaderMain
NewLab 411 ST Automatic Freezing Point
Category: Fuels and Oil Analysis
Sub Category: Others
Share
Add To Cart

According to the methods, the sample is cooled down and stirred. The solid hydrocarbon crystals formation are detected by means of a light beam throught fiber optic reflected thanks to a mirror. As soon as crystals are detected, the sample is warmed up until their complete disappearance.

ASTM D1655 - ASTM D2386
IP 16
Correlated:
ASTM D852 - ASTM D1493 - ASTM D5901 - ASTM D5972 - ASTM D6660 - ASTM D7153 - ASTM D7154
IP 435 - IP 528 - IP 529
ISO 3013
JIS K2276
DEF STAN91-091

Freezing Point of aviation fuels, aviation gasoline, aviation turbine fuels, engine coolants, antifreeze products, brake fluids, …
Solidification Point of Benzene.
Solidification Point of Industrial Organic Chemicals.

Measuring Parameters
  • Temperatures: in °C / °F
  • Measuring range: -110°C … +100°C
  • Range of analysis: -90°C … +55°C (410/2-SA)
  • Resolution: 0.01 °C
  • Accuracy: ± 0.1 °C
  • Repeatability / Reproducibility: as per standards methods or better

Software Features

New LabLink software able to manage up to 6 analytical heads simultaneously (stand alone)

  • User friendly interface
  • All analytical parameters recorded
  • Customizable analysis parameters and methods
  • Results report
  • Printable graphs and results - any Windows® compatible printer can be used
The software includes:
Analysis Menu
  • Standard method as per ASTM / IP / ISO / EN / DIN… norms of reference
  • Optional methods:
    • special detection of contaminants
  • Audible alarm and displayed messages at the end of the analysis and in case of errors and/or malfunctions
Diagnostic Menu
  • Direct access to all analog, digital, inputs and outputs
  • Selectable value displaying: °C / Volt
Calibration Menu
  • Automatic calibration of each temperature probe
  • Last calibration date referred to each single probe displayed and relative data printable
  • Display of calibration diagram
  • Insertion of offset values
  • Standard and advanced calibration modes
Data Utilities
  • Fields for introduction of operator and product name
  • Archive viewer for files recall
  • All analysis stored in Excel® compatible format
  • Storage capacity for more than 60’000 analysis
  • LIMS compatible

Integrated Touch Screen Panel PC
  • TFT/LCD 12"
  • Resolution 1024 × 768, 16.2 M colours
  • 2 USB ports for connection to an external printer and/or external PC
  • Storage capacity for more than 60'000 analysis

Test Jar
  • Same dimensions and volume as described by the standard test methods
  • Product level mark at 25 ml
  • Small edge on the top in order to fix the glass cell to the analytical head

Cooling System

Integrated gas CFC free motor compressors:

  • Single stage (for temperatures up to -40°C / 1)
  • Double stage (for temperatures up to -80°C / 2)

Equipped with an automatic energy power save system. After 15 minutes from the end of the analysis the cooling system goes in stand-by mode.


Safety Devices
  • Pressure controller for 1st stage motor compressor
  • Pressure controller for 2nd stage motor compressor
  • Thermostat for 2nd stage activation
  • Thermo-switch for each cooling / heating jacket
  • Motor compressors equipped with internal overload devices

Electrical Supply
  • 220V ± 15% / 50 to 60 Hz
  • 115V ± 15% / 60 Hz

Cord Cable
  • 3 conductors flexible cable 2 m (7 feet) length with PVC sheath oil and heat resistant as per CENELEC directives

Ambient Temperature
  • Max 32 °C
  • H.R. 80%
Dimensions (cm)1 test position2 test position3 test position4 test position6 test position
width6666100134130
depth6060606075
height80808080170
Weight (kg)
single stage compressor7090---
double stage compressor80100130160280
NewLab 411 ST.pdf
NewLab 411 ST.pdf